Fail-operational means more safety mechanisms to prove

novasom-fail-operational-l3-l4-safety-mechanisms.

A Level 2 system can hand control back to the driver as soon as something goes wrong. Level 3 and Level 4 systems cannot rely on that. When the vehicle is driving itself, a single hardware fault must not end in a loss of function: the system has to keep operating, or degrade in a controlled way, until the driver takes over or the vehicle reaches a minimal risk condition. The architecture moves from fail-safe to fail-operational.

Work on the third edition of ISO 26262, expected around 2027, is taking place against this background. Whatever the final text says, the engineering consequence is already visible on today’s L3/L4 boards.

Redundancy multiplies safety mechanisms

Fail-operational behaviour is built on redundancy: duplicated or diverse power paths, redundant processing channels, cross-monitoring between controllers, independent supervisors that decide which channel is healthy. Each of these elements is a safety mechanism, and each one must detect faults and then switch, isolate or degrade correctly.

Almost all of them live inside the board: the rail that feeds the second channel, the monitor that compares the two, the link over which they exchange heartbeats, the switch that isolates the failed path. None of these signals is on the connector.

Two questions the FMEDA alone cannot answer

  • Does the switchover really happen within the fault tolerant time interval? Timing is the core of fail-operational design. An analysis can estimate it; only a measurement can confirm it.
  • Are the redundant paths free of latent faults? A backup channel that has silently failed is the classic latent fault, and ASIL C and D programs must show that such faults are detected. Testing that means injecting faults on internal nodes of the backup path and checking that the diagnostics see them.

The numbers grow quickly. On a board with 3,000–4,000 components, safety-analysis tools generate 10,000–20,000 fault scenarios: single faults, double faults and, where relevant, multiple faults. Between a quarter and a half of them deserve a physical test, and most sit on nodes that connector-level HIL cannot reach.

Testing redundancy where it lives

Novasom’s hardware fault injection system reaches those nodes through a dedicated bed-of-nails fixture, co-designed with your FMEDA, on more than 500 internal test points. Each point can inject voltage or current with 16-bit resolution and read the response on the same point: a rail drifting out of tolerance on one channel, a disturbed I²C or SPI link between monitors, an open or shorted enable line.

Because every actuation and reading is timestamped at 0.25 µs (4 MHz timebase), the campaign shows not only that the second channel took over, but when: the time from fault to detection and from detection to reaction, cycle after cycle, in the same sequence every time. The system runs fully embedded, with no PC in the loop, unattended for weeks, and its open API lets your FMEDA or FTA tools drive the campaign.

Complementary to what you already have

Your connector-level HIL keeps testing how the ECU reacts to faults in the harness and on the vehicle network. Internal fault injection adds the part that fail-operational design depends on: proof that the redundancy inside the board works the way the safety analysis says it does.

Your FMEDA says your redundancy works. We show it on the real board, fault after fault, timestamped.

Customer programs are under NDA, so we show the system running on our reference hardware. Book a live demo.