For years, a safety case had one main reader: the assessor. That is changing. The revised EU Product Liability Directive, (EU) 2024/2853, must be transposed by Member States by 9 December 2026. It explicitly treats software as a product, and it gives courts new tools: they can order the disclosure of technical evidence, and they can presume a defect when a product is too complex for the injured party to prove it.
For suppliers of Level 3 and Level 4 automated driving components, the consequence is simple: the evidence you produce for ISO 26262 is the same evidence you may one day have to show in a liability case. Legal analyses of the German framework for automated driving already draw this conclusion: validation evidence should be documented to a standard that serves both type approval and product liability.
What a safety case usually contains today
On an ASIL C or D program, the hardware metrics (single-point fault metric, latent fault metric and PMHF) rest on the diagnostic coverage claimed for each safety mechanism. In many FMEDAs that coverage comes from the reference values of ISO 26262-5, Annex D: low, medium and high, that is 60, 90 and 99%. The analysis is correct, but it is an analysis. It states that a voltage monitor, a watchdog or a bus check will detect a fault. It does not show it.
An assessor may accept that. A lawyer, an expert witness or a court asking “how do you know this mechanism worked?” is a different reader.
Analysis claims. Testing proves.
Hardware fault injection turns a claim into an observation. A fault is physically injected on the real PCBA, and the reaction of the safety mechanism (detection, reaction, safe state within the fault tolerant time interval) is measured and recorded.
The difficulty is access. Most safety mechanisms live on internal nodes: supply rails and their monitors, I²C and SPI links between the MCU and the safety companion, internal enable lines. On a multilayer board those nodes never reach the connector, so connector-level HIL cannot exercise them. Where a safety mechanism can only be exercised from an internal node, internal fault injection is the only way to produce experimental evidence.
What makes evidence defensible
- It comes from the real hardware: production boards, not modified samples with wires soldered on.
- It is traceable to the FMEDA: each injected fault corresponds to a safety-relevant fault identified in your FMEDA, so the test record maps directly onto the analysis.
- It is timestamped: when was the fault applied, when did the mechanism react, how long did the system take to reach its safe state? Without a time reference, a test result is an anecdote.
- It is repeatable: the same campaign, run again on the next hardware revision, must give comparable results.
How Novasom produces it
Novasom’s hardware fault injection system works through a dedicated bed-of-nails fixture, designed together with your FMEDA, that contacts the internal test points of the board: more than 500 of them on field-proven fixtures. On each point, embedded real-time boards inject voltage or current with 16-bit resolution and read the static and dynamic response on the same point.
Every actuation and every reading is timestamped at 0.25 µs (4 MHz timebase). A single injection event takes 5–6 ms; a full sweep of 500+ points completes in a few hundred milliseconds, identically on every cycle. The system is fully embedded, with no PC or general-purpose operating system in the loop, so campaigns run unattended for days or weeks. The output is a log in which every fault, every reaction and every time interval can be traced back to a line of the FMEDA.
Complementary, not a replacement
Fault injection does not replace the FMEDA or the connector-level HIL you already use, and faults inside the silicon remain covered by analysis. What changes is the status of the claims you can test: the diagnostic coverage and latent-fault detection of the board’s internal safety mechanisms become measured results instead of assumed values.
Default diagnostic-coverage values are not evidence. Measured, timestamped results are.
This article is a technical reading of the market, not legal advice. For the legal implications of the Product Liability Directive for your products, consult your legal counsel.
See it on real hardware
Customer programs are under NDA, so we show the system running on our reference hardware. Book a live demo or a technical session with our engineers.