ADAS HIL Testing

HIL test benches with hardware fault injection for L3/L4 ADAS ECUs
Your HIL already tests how an ECU reacts to its environment. We add what connector-level testing cannot reach: faults inside the board, injected deterministically and timestamped — evidence for ISO 26262 ASIL C/D.

What ADAS HIL testing covers — and what it misses

A typical ADAS HIL test bench simulates sensors, buses and driving scenarios, and inserts faults at the ECU connector: open lines, shorts to ground, to battery or to another pin. It is the right tool to validate functions and the reaction to external faults.

On ASIL C/D programs, however, many safety mechanisms live inside the PCBA: supply voltage monitors, internal I²C/SPI buses between MCU, sensors and safety companion, nodes on multilayer boards that never reach the connector. Connector-level fault insertion was not designed for these nodes — so their diagnostic coverage is often left to default values in the FMEDA.

Novasom closes that gap. Where a safety mechanism can only be exercised from an internal node, internal fault injection is the only way to produce experimental evidence.

Novasom Industries validation

A fault injection test bench built around your PCBA

A dedicated bed-of-nails fixture, designed together with your FMEDA, contacts 500+ internal test points of the production board. On each point, embedded real-time boards inject voltage or current with 16-bit resolution and read static and dynamic signals back on the same point.

  • 5–6 ms per injection event; a full sweep of 500+ points in 200–300 ms, identical every cycle
  • Every actuation and reading timestamped at 0.25 µs (4 MHz timebase)
  • Fully embedded, no PC in the loop: campaigns run unattended for days or weeks
  • Open API: drive it from scripts, FMEDA/FTA toolchains or your test automation
  • No soldered wires: production hardware is tested unmodified, through its test pads

Complementary to your existing HIL. Keep connector-level tests where they are; Novasom adds the internal nodes. The fault injection bench can run alongside your HIL and SIL environment, controlled by messages from your test sequencer.

ADAS HIL testing — frequently asked questions

What does hardware fault injection add to ADAS HIL testing?
Connector-level HIL shows how the ECU reacts to a broken harness. In-circuit hardware fault injection shows how its internal safety mechanisms react to an internal fault: a rail out of tolerance, a disturbed I²C/SPI bus, an open or shorted node.

Can a HIL test bench demonstrate diagnostic coverage?
Yes, for the faults it can reach. Injecting every safety-relevant fault identified in your FMEDA on the real PCBA turns declared diagnostic coverage into measured evidence — including latent faults (LFM) required for ASIL C/D. It complements the FMEDA, it does not replace it.

How large can a campaign be?
In a program for a global supplier of L3 and L4 automated driving systems, an ASIL D ADAS ECU was tested on about 550 internal points and around 12,000 fault scenarios, iterating on the same fixture until no open fault remained.

Which faults are covered?
Single and double faults, and multiple faults where relevant, as derived from your safety analysis. Faults inside the silicon remain covered by analysis.

Can we see it running?
Customer programs are under NDA, but our reference hardware is ready: book a live demo or a remote technical session.

Deutsch: Hardware-Fehlerinjektion für ISO 26262 · Compare: Fault insertion unit vs in-circuit fault injection

At your service 24/7

You ask, we will solve all your problems!

Live demo

See in-circuit fault injection running on our reference hardware, on site or remotely.

Technical session

Discuss your ASIL C/D program, your FMEDA and your test points with our engineers.

ADAS HIL testing